Valve testing, maintenance and repair, from Subang Jaya
Optimus Distributor, a valve distributor in Subang Jaya, Selangor, also tests, maintains and repairs valves, so a valve in service keeps doing its job. Testing checks a valve's performance for proper flow control. Maintenance services it to keep it running smoothly and avoid costly issues. Repair means inspecting, cleaning and replacing parts to fix leaks and prevent downtime.
- Services
- Testing · Maintenance · Repair
- Base
- Jalan Tiara 3, Subang Jaya
- Since
- 2013
- Quality
- ISO 9001:2015
- Registered
- MOF · TNB
What each service covers
Our company profile puts it plainly: we are equipped to handle all aspects of valve management, so that valves operate efficiently and safely throughout their lifecycle. It names three services:
- Testing: we check valve performance to ensure proper flow control
- Maintenance: we service valves to keep them running smoothly and avoid costly issues
- Repair: we inspect, clean and replace parts to fix leaks and prevent downtime
We do not just sell parts: we sit down with your engineers to make sure the valve fits the service.
Not every valve is worth opening
Whether a valve is repaired or replaced depends on its pattern, size and service. As our gate valve vs ball valve guide sets out, packing and seat faces are serviceable in line on larger cast gate valves, while small-bore ball valves are usually replaced rather than repaired. Send us the details and we tell you what we can do for that valve.
One rule holds for fire-safe valves: rebuild them with the maker's specified parts. A repair is no substitute for a fire type test, as our guide to fire-safe ball valves explains.
Upkeep the makers build into the lines we supply
| Line | What the maker builds in | Why it helps |
|---|---|---|
| Pettinaroli Dynasty 92 PICV | Made for heavily contaminated water; the internals can be removed, cleaned and replaced | Dirt is dealt with at the valve, without changing it |
| Pettinaroli FilterBall | Strainer lifts out (51F, 52F), flushes through a drain outlet (51FS, 52FS) or back-flushes (56F/2) | The screen is cleaned at the valve itself |
| Pettinaroli HVAC and data centre kits | Valve test points, pressure and temperature gauges, a flushing by-pass | Pressure and temperature can be read in place, and pipes flushed past the control valve |
| Pettinaroli ST2D strainer, SB2V balancing valve | A test port on the body | A reading at the valve, without breaking the line |
| KITZ Y-strainers | Clean when the pressure difference approaches 0.1 MPa (1 bar); screens sold as maintenance parts | A number to clean by, and a spare screen to fit |
These are the makers' own features, not part of our service. From Pettinaroli's HVAC catalogue, FilterBall leaflet and our own Pettinaroli flyer, and KITZ's FAQ. Ask for the maker's maintenance instructions for the exact model you hold.
What to send us
How much does a valve repair cost?
It depends on the valve, its size and what is wrong with it, so we quote each job once we have the details. Ask for the turnaround at the same time.
Which valves can you test, maintain or repair?
Send the make, model and size, and we confirm what we can do for that valve.
Why use Optimus Distributor?
We have been in business since 2013, are ISO 9001:2015 certified and are registered with the Ministry of Finance and with TNB. We were appointed KITZ's authorised distributor in 2019, and the industries we serve include commercial, palm oil refining, oil and gas, petrochemical, pharmaceutical, power, shipyards and water works.
What should I send?
- Make, model, size and rating, or a photo of the nameplate
- What is wrong: leaking, passing, sticking, or due for a check
- Fluid, pressure and temperature in service
- How many valves, and where they are installed
- The date you need them back in service


Tell us the valve and the fault.
Make, model, size and what is wrong. We come back with what we can do and the price.
OPTIMUS DISTRIBUTOR